TLV SJ3FNB and SJ3FVB ductile cast iron free float steam traps with thermostatic bimetal air venting. Features three-point seating, up to 22 barg PMO, and 220°C TMO.

TLV SJ3FNB and SJ3FVB are reliable and durable ductile cast iron free float steam traps with tight shut-off for use on small to medium process equipment. The SJ3FNB is designed for horizontal piping installation, while the SJ3FVB is designed for vertical piping installation. They feature an integral plate-type bimetal air vent unit for rapid startup.
The self-modulating free float provides continuous, smooth, low velocity condensate discharge as process loads vary. A precision-ground float, constant water seal, and three-point seating design ensure a steam-tight seal, even under no-load conditions. The built-in screen with a large surface area ensures extended trouble-free operation, and easy, inline access to internal parts simplifies cleaning and reduces maintenance costs.
| No. | Description | Material | DIN | ASTM/AISI |
|---|---|---|---|---|
| 1 | Body | Ductile Cast Iron GGG40.3 | 0.7043 | A395 Gr.60-40-18 |
| 2 | Cover | Ductile Cast Iron GGG40.3 | 0.7043 | A395 Gr.60-40-18 |
| 3 | Float | Stainless Steel SUS316L | 1.4404 | AISI316L |
| 5 | Orifice Gasket | Fluorine Resin PTFE | PTFE | PTFE |
| 6 | Screen | Stainless Steel SUS304 | 1.4312 | AISI304 |
| 8 | Cover Gasket | Fluorine Resin PTFE | PTFE | PTFE |
| 17 | Bimetal Plate | - | - | - |
WARNING
To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside of the specification range. Local regulations may restrict the use of this product to below the conditions quoted. Maximum allowable pressure (PMA) and maximum allowable temperature (TMA) are PRESSURE SHELL DESIGN CONDITIONS, NOT OPERATING CONDITIONS.

| DN (DIN 2501 PN25/40) | L (mm) | H (mm) | W (mm) | B (mm) | Weight (kg) |
|---|---|---|---|---|---|
| 15 | 150 | 160 | 180 | 100 | 6.0 |
| 20 | 150 | 160 | 180 | 100 | 6.4 |
| 25 | 160 | 160 | 185 | 100 | 6.9 |

| DN (DIN 2501 PN25/40) | L (mm) | W1* (mm) | B1* (mm) | Weight (kg) |
|---|---|---|---|---|
| 15 | 150 | 155 | 70 | 5.1 |
| 20 | 150 | 155 | 70 | 5.6 |
| 25 | 160 | 155 | 70 | 6.3 |
(Approximate values)

INFO


Piping Arrangement Checklist
Operational inspections should be performed at least twice per year, or as called for by trap operating conditions. Steam trap failure may result in temperature drop in the equipment, poor product quality or losses due to steam leakage.
DANGER
NEVER apply direct heat to the float. The float may explode due to increased internal pressure, causing accidents leading to serious injury or property and equipment damage.
| Part | Inspection Procedure |
|---|---|
| Body, Cover | Check inside for damage, dirt, grease, oil film, rust or scale |
| Gaskets | Check for warping or damage |
| Bimetal Unit | Check for damage |
| Screen | Check for clogging, corrosion or damage |
| Float | Check for deformation, damage, oil film or water inside |
| Air Vent Valve Seat, Orifice | Check for rust, scale, oil film, wear or damage |
| Part | Torque (N·m) | Distance Across Flats (mm) |
|---|---|---|
| Cover Bolt | 60 | 16, 17 |
| Orifice | 40 | 17 |
| Screen Holder | 140 | 24 (SJ3FNB) / 38 (SJ3FVB) |
| Drain Plug | 30 | 12 |
| Element Cover | 140 | 32 |
| Air Vent Valve Seat | 35 | 19 |
| Orifice Plug (SJ3FNB) | 140 | 38 |
If the expected performance is unachievable after installation, check the following points:
| Problem | Cause | Remedy |
|---|---|---|
| No condensate is discharged or discharge is poor | Float is damaged or filled with condensate | Replace the float |
| Orifice, screen or piping is clogged with rust or scale | Clean | |
| Steam-locking has occurred | Blowdown through the bypass or close the trap inlet valve and allow the trap to cool | |
| Bimetal element is damaged | Replace the bimetal unit | |
| Operating pressure exceeds maximum specified pressure, or insufficient differential pressure | Compare specifications and actual operating conditions | |
| Steam is discharged or leaks from the trap outlet | Rust and scale have accumulated around the orifice or under the float | Clean |
| Orifice is damaged | Replace the orifice | |
| Float is deformed or coated with scale | Clean or replace the float | |
| Trap is installed above the maximum allowable inclination angle | Correct the installation | |
| Vibration of trap occurs | Lengthen inlet piping, then fasten it securely | |
| Steam leaks from a place other than the trap outlet | Deterioration of or damage to gaskets | Replace with new gaskets |
| Improper tightening torque for cover was used | Tighten to the proper torque |