TLV iT5-IS-TPN TrapSensor is an intrinsically safe wireless monitoring sensor for simultaneous temperature and pressure measurement up to 400 °C, based on ISA 100.11a.

TLV iT5-IS-TPN Wireless Temperature and Pressure Monitoring Sensor

The TLV iT5-IS-TPN TrapSensor is a wireless monitoring sensor designed for high-frequency monitoring of crucial steam-using equipment such as heat exchangers, pumps, turbines, and equipment with the possibility of air present in steam piping. It provides simultaneous temperature and pressure measurement based on the ISA 100.11A communication protocol.

TLV iT5-IS-TPN wireless monitoring sensor overview

Features

  • Simultaneous temperature and pressure measurement.
  • High frequency monitoring: measurement cycles configurable between 1 second and 1 hour.
  • Line-of-sight communication distance of 400 m between sensor and repeater or between repeaters.
  • Powered by a long-life battery pack, replaceable in hazardous locations.
  • Temperature measurement up to 400 °C.
  • Intrinsically safe construction for use in hazardous and nonhazardous locations.
  • Optional extended antenna type for remote antenna mounting.

Specifications

ModeliT5-IS-TPN
Maximum Measurement Temperature (°C)400
Measurable Temperature Range (°C)-40 to +400
Measurable Temperature Accuracy (°C)±1
Minimum Ambient Temperature (°C)-40
Maximum Ambient Temperature (°C)-40 to < 125: 80
125 to < 200: 75
200 to < 300: 68
300 to < 400: 64
Measurable Pressure Range0 to 2 MPaG, 0 to 5 MPaG
Measurable Pressure Accuracy±0.5% of full-scale
Maximum Allowable PressureRated pressure × 2
Applicable FluidsSteam, water, air, nitrogen
Wireless Frequency Band2.4 GHz
Maximum No. of Connections500 devices per gateway
Maximum No. of Hops4 (from access point to sensor)
Measurement Cycle1 second to 1 hour
Power SourceNon-rechargeable lithium-thionyl chloride battery pack (Rated Voltage: 3.6 V, Rated Capacity: 38 Ah)
Battery Life10 years for regular operation (60 s measurement cycle)
Intrinsic Safety SpecificationsATEX: II 1G Ex ia op is IIC T4 Ga
UL/cUL: Class I, Division 1, Groups ABCD
IECEx: Ex ia op is IIC T4 Ga, Class I, Zone 0, AEx ia op is IIC T4, Ex ia op is IIC T4
UKEX: Ex ia op is IIC T4 Ga
Connection TypeCompression Fitting: Screwed Rc(PT) 15 mm
Thermowell: Flanged 25 mm
Communication ProtocolISA 100.11a, based on IEEE 802.15.4
Regulatory ComplianceFCC, IC, CE compliant
Frequency Bandwidth2.405 to 2.480 GHz
Transmitter Power Output7.0 mW/MHz
Communication DistanceApprox. 400 m (with a clear line of sight)
Protection ClassIP66 and IP67 (evaluation for intrinsic safety is performed at IP20)
Body, Cover MaterialAluminium Alloy Die Castings (ADC3, SG100A)
Sensor Tip MaterialStainless Steel (SUS304)
Thermowell MaterialStainless Steel (A182 F316)
OptionsExtended antenna type: Sensor with 150 mm antenna and 3 m or 13 m cable (intrinsically safe)

Notes on Specifications

  • Maximum number of connections applies when using TLV-recommended system (Yokogawa Electric Corporation: YFGW410).
  • Measurement cycle can be configured per sensor. Configurable cycle varies depending on gateway used.
  • Battery pack can be replaced in hazardous locations.
  • Battery life is given for an ambient temperature of 25 °C and may vary depending on environmental conditions such as gateway used, transmission status and ambient temperature.
  • Communication distance depends on environmental conditions and installation location.

Dimensions

iT5-IS-TPN Screwed (Compression Fitting)

TLV iT5-IS-TPN screwed compression fitting dimensions

Size (mm)Weight (kg)
152.0

Rc(PT), other standards available.

iT5-IS-TPN Flanged (Thermowell)

Size (mm)Connect to ASME ClassWeight (kg)
25300RF, 600RF6.0 [6.2]

Other standards available. Contact TLV for details. [ ] 600RF

Options

Antenna Extension

TLV iT5-IS-TPN optional antenna extension

System Configuration Example

TLV iT5-IS-TPN system configuration example

No.ModelFunction
Sensor: iT5-IS-TPNMeasurement of temperature and pressure, wireless transmission of information
Repeater: iT5-IS-RUNWireless relay of information
Access Point/GatewayRelay of information via intranet
Data Collection ServerImporting collected data