BURKERT 344633 Type 2000 pneumatically operated 2/2-way angle seat valve. Features a stainless steel body, clamp connection, PTFE seal, and handles up to 11 bar operating pressure.

BURKERT 344633 (Type 2000) is an externally piloted angle seat valve operated with a single-acting piston actuator. The actuator is made of PA (Polyamide), suitable for demanding ambient temperatures. High flow rates are attained with the virtually straight flow path of the 2/2-way stainless steel body. The reliable self-adjusting packing gland provides high sealing integrity. This maintenance-free and robust valve features a clamp connection and PTFE seat seal, making it ideal for the controlled flow of liquid and gaseous media in industrial and hygienic applications.

| No. | Element | Material (Stainless steel body CF3M with PA actuator) |
|---|---|---|
| 1 | Transparent cover | PC |
| 2 | Pilot air ports | Stainless steel 1.4305 |
| 3 | Actuator | PA |
| 4 | Piston seal | NBR |
| 5 | Packing gland | PTFE V-Rings (filled), with spring compensation |
| 6 | Spring | Stainless steel 1.4310 |
| 7 | Pipe | Stainless steel CF3M |
| 8 | Wiper | PTFE (filled) |
| 9 | Body seal | Graphite, PTFE (option) |
| 10 | Spindle | Stainless steel 1.4401 / 1.4404 |
| 11 | Pin | Stainless steel 1.4401 / 1.4404 |
| 12 | Seat seal | PTFE |
| 13 | Valve body | Stainless steel CF3M |
| 14 | Swivel plate | Stainless steel CF3M / 1.4401 / 1.4404 |
| Symbol | Description |
|---|---|
| Control function A (CF A) | Pneumatically operated 2/2-way on/off valve. Flow direction below seat. Normally closed by spring force. |
| Control function B (CF B) | Pneumatically operated 2/2-way on/off valve. Flow direction below seat. Normally opened by spring force. |
Risk of damage due to bursting pipes
Risk of damage due to bursting pipes and bursting equipment when the flow is above the seat. In the case of liquid mediums, water hammer can occur, causing pipes and the device to burst. Do not use valves with flow above the seat for liquid mediums.
| Property | Value |
|---|---|
| Operating pressure | 0 bar(g)...25 bar(g), vacuum variants...-0.9 bar(g) (option) |
| Nominal pressure | PN 25 (DIN EN 1333), Class 150 (DIN EN 1759) |
| Pilot pressure | 2...10 bar(g) |
| Seat leakage | Leakage rate A (DIN EN 12266-1), seat seal PTFE and PEEK, test medium air |
| Operating medium | Steam, water, neutral gases, alcohols, oils, fuels, hydraulic fluids, salt solutions, alkalis, organic solvents, oxygen and fuel gases |
| Medium temperature | -40...+230 °C (depending on variant) |
| Viscosity | Max. 600 mm²/s |
| Control medium | Air, neutral gases |
| Ambient temperature | -40...+60 °C (for PA actuator) |
| Degree of protection | IP67 |
| Installation position | As required, preferably with actuator upright |

Note: The dimensions for B, H, K, M, HS and BS are maximum dimensions and may be up to 6 mm less, depending on the nominal diameter and standard.
Installation Recommendation
The angle seat valve can be installed in any position, preferably with the actuator face up. Before connecting the valve, ensure the pipelines are flush and stress-free. Observe the direction of flow.
High Pressure Hazard
Risk of injury from high pressure in the system! Turn off the pressure and vent the lines before loosening lines or valves.
Maintenance Work: The actuator of the angle seat valve is maintenance-free. Parts which are subject to natural wear include the pendulum disc and graphite seal. If leaks occur, replace the particular wearing part with an appropriate original spare part.