Bürkert 21155 (Type 0290) servo-assisted 2/2-way solenoid valve. Features a stainless steel body, FKM seal, G1/2 internal thread, 24V operation, and 0-16 bar pressure range.

Bürkert 21155 (Type 0290) is a servo-assisted 2/2-way diaphragm valve. The valve opens without differential pressure. The opening process is facilitated by the fix-coupling of the diaphragm to the magnetic core. The integrated 'soft-kick' function ensures gentle opening. The solenoid coils are moulded with an epoxy that has a high level of chemical resistance. Kick and drop electronics are moulded into the solenoid for reduced electrical power consumption.
Circuit function A (CF A): 2/2-way solenoid valve, servo-controlled, normally closed.

| No. | Element | Material (Stainless Steel Variant) |
|---|---|---|
| 1 | Coil | Epoxy |
| 2 | Stopper | Stainless steel 1.4105, 1.4113 or 1.4523 (optional) |
| 3 | Shading ring | Silver |
| 4 | Spring | Stainless steel 1.4310 |
| 5 | Magnetic core | Stainless steel 1.4105 or 1.4113 |
| 6 | Core guide tube | Stainless steel 1.4303 |
| 7-9 | O-ring | FKM |
| 10 | Diaphragm plate | Stainless steel 1.4401 |
| 11 | Diaphragm | FKM |
| 12 | Body | Stainless steel 1.4581 |
| 13 | Pilot valve seat | Stainless steel 1.4401 |
| 14 | Seat seal | FKM |
INFO
Dimensions in mm. The dimensions D1 and F1 apply to G thread.

| DN | A | B | G (D1) | G (F1) | E | L | SW | J | H |
|---|---|---|---|---|---|---|---|---|---|
| 12 | 80 | 94 | G 1/2 | 14 | 40 | 74.5 | 27 | 81 | 40 |
Power consumption
| Orifice | Kv value water P→A | Port connection | Inrush power (AC/DC) | Holding power (AC/DC) | Weight |
|---|---|---|---|---|---|
| 12 mm | 1.8 m³/h | G 1/2 | 80 W | 25 VA / 10 W | 1.0 kg |
TIP
The coil with Kick and Drop electronics is a universal current coil (frequency coding: UC) that is suitable for AC and DC.
DANGER
Risk of injury from high pressure in the system Before loosening lines or valves, switch off the pressure and vent the lines.
Risk of injury from electric shock Before accessing the device or the system, switch off the power supply and secure it to prevent reactivation! Observe the applicable accident prevention and safety regulations for electrical devices.
Before Installation
Installation position: The installation position is flexible. Preferably: actuator at the top.
Dirt trap: For safe operation of the solenoid valve, a dirt trap (≤400µm) must be installed before the valve inlet.
WARNING
If there is no protective conductor function between the coil and body, there is a risk of injury from electric shock. Always connect the protective conductor. Check the protective conductor function after installing the coil.

Screw cable plug tight, ensuring a maximum torque of 1 Nm. Check that the seal is properly fitted. Connect protective conductor and check electrical continuity between coil and body.