Yoshitake AL-32 series closed type safety relief valve. Made of stainless steel with excellent corrosion resistance. Suitable for steam, air, water, oil, and non-dangerous fluids. JIS 10K flanged connection.

Yoshitake AL-32 series safety relief valves are used mainly in various pressure vessels, instrumentation devices, and at the outlet of pressure reducing valves to prevent accidents caused by abnormal pressure rise. The series features all stainless steel trim parts offering high corrosion resistance, and a closed structure that prevents fluid leakage. Closed lever types (AL-32ML, AL-32TML) can be manually inspected for blowout.

| Model | AL-32 | AL-32T | AL-32ML | AL-32TML |
|---|---|---|---|---|
| Structure | Closed type | Closed type | Closed type with a lever | Closed type with a lever |
| Application | Steam, Air, Cold and hot water, Oil, Other non-dangerous fluids | Air, cold and hot water, Oil, Other non-dangerous fluids | Steam, Air, Cold and hot water, Oil, Other non-dangerous fluids | Air, cold and hot water, Oil, Other non-dangerous fluids |
| Working pressure | 0.05-1.0 MPa | 0.05-1.0 MPa | 0.05-1.0 MPa | 0.05-1.0 MPa |
| Working temperature | 5-220°C* | 5-120°C | 5-220°C* | 5-120°C |
| Connection | JIS 10K loose flanged | JIS 10K loose flanged | JIS 10K loose flanged | JIS 10K loose flanged |
| Nominal size | 15-50A | 15-50A | 15-50A | 15-50A |
| Material (Spring case) | Cast stainless steel | Cast stainless steel | Cast stainless steel | Cast stainless steel |
| Material (Valve, valve seat) | Stainless steel | Stainless steel | Stainless steel | Stainless steel |
| Material (Spring) | Stainless steel | Stainless steel | Stainless steel | Stainless steel |
| Material (O ring) | - | Composition rubber | - | Composition rubber |
*The maximum temperature is 150°C when the fluid is liquid. AL-32T is recommended for hot and cold water applications.
WARNING



| Nominal size | Flow area πDe (mm²) | D (mm) | L (mm) | H1 (mm) | H (mm) AL-32 / AL-32T | H (mm) AL-32ML / AL-32TML | Weight (kg) AL-32 / AL-32T | Weight (kg) AL-32ML / AL-32TML |
|---|---|---|---|---|---|---|---|---|
| 15A | 20.1 | 16 | 63 | 97 | 185 | 215 | 2.4 | 2.5 |
| 20A | 34.6 | 21 | 87 | 101 | 187 | 217 | 2.8 | 2.9 |
| 25A | 53.0 | 26 | 92 | 119 | 215 | 245 | 4.4 | 4.5 |
| 32A | 93.3 | 33 | 99 | 135 | 255 | 284 | 5.2 | 5.3 |
| 40A | 135.2 | 41 | 109 | 140 | 281 | 321 | 6.5 | 6.7 |
| 50A | 208.2 | 51 | 114 | 162 | 332 | 372 | 11.3 | 11.5 |
*The outlet flange is 1 size larger than the nominal size.


| No. | Part name | No. | Part name |
|---|---|---|---|
| 1 | Spring case | 11 | Cap |
| 2 | Valve seat | 12 | Gasket |
| 3 | Valve | 13 | Gasket |
| 4 | O-ring | 14 | Name plate |
| 5 | Spindle | 15 | Lever |
| 6 | Spring | 16 | Spring pin |
| 7 | Bottom spring plate | 17 | O ring |
| 8 | Top spring plate | 18 | Connecting rod |
| 9 | Adjusting screw | 19 | Spring pin |
| 10 | Lock nut | 20 | Pressure groove |
Blowout operation: As the inlet pressure approaches the blowout pressure, the force of fluid pushing up the valve approaches the force of the spring pressing down the valve. The safety relief valve commences to blow when the inlet pressure reaches around 3% below the blowout pressure. The fluid accumulates gradually on the pressure groove and when the fluid pressure reaches the blowout pressure the valve pops.
Closing operation: Since the inlet pressure of the safety relief valve decreases when the fluid is released into the atmosphere by the pop action of the valve, the force of fluid lift is lowered. At this point, the repelling force of the spring becomes larger than the force of fluid lift and thus the valve closes. In addition, while the safety relief valve discharges, pressure of fluid entering into the back of the valve (back pressure) adds to the closing force.
Capacity (Pressure vessel structure standard) [kg/h]
| Nominal size | 0.05 MPa | 0.1 MPa | 0.2 MPa | 0.3 MPa | 0.4 MPa | 0.5 MPa | 0.6 MPa | 0.7 MPa | 0.8 MPa | 0.9 MPa | 1.0 MPa |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 15A | 15 | 20 | 29 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 109 |
| 20A | 27 | 35 | 51 | 69 | 87 | 104 | 121 | 138 | 155 | 172 | 189 |
| 25A | 42 | 54 | 78 | 105 | 133 | 159 | 186 | 212 | 237 | 263 | 289 |
| 32A | 70 | 91 | 132 | 178 | 224 | 268 | 313 | 356 | 400 | 443 | 487 |
| 40A | 105 | 136 | 198 | 266 | 335 | 402 | 468 | 534 | 599 | 664 | 729 |
| 50A | 163 | 211 | 306 | 411 | 518 | 621 | 723 | 824 | 924 | 1025 | 1126 |
Capacity (Pressure vessel structure standard) [kg/h]
| Nominal size | 0.05 MPa | 0.1 MPa | 0.2 MPa | 0.3 MPa | 0.4 MPa | 0.5 MPa | 0.6 MPa | 0.7 MPa | 0.8 MPa | 0.9 MPa | 1.0 MPa |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 15A | 25 | 33 | 48 | 65 | 81 | 98 | 114 | 131 | 147 | 164 | 181 |
| 20A | 44 | 57 | 83 | 111 | 140 | 169 | 197 | 226 | 254 | 283 | 311 |
| 25A | 67 | 87 | 127 | 171 | 215 | 258 | 302 | 346 | 390 | 433 | 477 |
| 32A | 113 | 147 | 214 | 288 | 362 | 435 | 509 | 582 | 656 | 730 | 803 |
| 40A | 169 | 221 | 321 | 431 | 542 | 652 | 762 | 872 | 982 | 1093 | 1203 |
| 50A | 262 | 341 | 496 | 666 | 836 | 1006 | 1176 | 1346 | 1516 | 1687 | 1857 |
Capacity (Yoshitake standard) [m³/h]
| Nominal size | 0.05 MPa | 0.1 MPa | 0.2 MPa | 0.3 MPa | 0.4 MPa | 0.5 MPa | 0.6 MPa | 0.7 MPa | 0.8 MPa | 0.9 MPa | 1.0 MPa |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 15A | 0.4 | 0.5 | 0.9 | 1.1 | 1.3 | 1.5 | 1.6 | 1.8 | 1.9 | 2.0 | 2.1 |
| 20A | 0.6 | 0.9 | 1.6 | 2.0 | 2.3 | 2.6 | 2.8 | 3.1 | 3.3 | 3.5 | 3.7 |
| 25A | 1.0 | 1.5 | 2.5 | 3.1 | 3.6 | 4.0 | 4.4 | 4.7 | 5.1 | 5.4 | 5.7 |
| 32A | 1.8 | 2.6 | 4.5 | 5.5 | 6.3 | 7.1 | 7.8 | 8.4 | 9.0 | 9.5 | 10.0 |
| 40A | 2.7 | 3.8 | 6.5 | 7.9 | 9.2 | 10.3 | 11.3 | 12.2 | 13.0 | 13.8 | 14.6 |
| 50A | 4.1 | 5.9 | 10.0 | 12.3 | 14.2 | 15.9 | 17.4 | 18.8 | 20.1 | 21.3 | 22.4 |
INFO
[Example] When the set pressure is 1.0 MPa, and the valve size is 50A: The capacity is 22.4 m³/h, when the inlet pressure reaches 1.25 MPa (accumulation becomes 25%) after the fluid pressure reaches the set pressure of 1.0 MPa.
DANGER
WARNING

Check the following items while the system is in operation:
The differential Pressure in which the blow-off inspection by lever operation is possible:
| Size | Differential pressure between set and inlet pressure |
|---|---|
| 15-25A | 1.0 MPa or less |
| 32-40A | 0.6 MPa or less |
| 50A | 0.4 MPa or less |