Skip to content
Direct-ActingNormally ClosedIP65

BURKERT 389794 Direct-Acting 2/2-Way Plunger Valve

BURKERT 389794 (Type 7011) is a direct-acting 2/2-way normally closed plunger valve. Features an M5 port, 2.0mm orifice, stainless steel body, FKM seal, and operates at 230V/50Hz up to 22 bar.

BURKERT 389794 Direct-Acting 2/2-Way Plunger Valve

BURKERT 389794 (Type 7011) is a direct-acting and compact small 2/2-way plunger valve. The stopper and the core guide tube are welded together to increase pressure resistance and leak-tightness. This specific model features an M5 threaded port, a 2.0 mm orifice, a stainless steel body, and FKM seals. It operates on 230 V / 50 Hz with a power consumption of 6 W, supporting a pressure range of 0 to 22 bar. In combination with a plug conforming to industry standard form B, the valve satisfies degree of protection IP65.

General Technical Data

FeatureSpecification
Seal materialFKM
Body materialStainless steel 1.4305/303
OrificeDN 2.0
Circuit functionA (Normally closed)
Thermal insulation classEpoxy coil class H
Duty cycle100% continuous operation
Operating voltage230 V 50 Hz
Medium temperature-10 °C to +100 °C
Port connectionM5

Circuit Function

Circuit function A (CF A): 2/2-way solenoid valve, direct-acting, normally closed.

BURKERT 389794 Circuit function A

Material Specifications

Standard variant circuit function A

BURKERT 389794 Material specifications

No.ElementMaterial
1NutDIN 176 Surface finish thick film passivated KOSA0101
2StopperStainless steel 1.4113/434
3Core guide tubeStainless steel 1.4303 ST/305L
4Shading ringCopper (optional silver)
5CoreStainless steel 1.4113/434
6SpringStainless steel 1.4310/301
7SealFKM
8Valve bodyStainless steel 1.4305/303
9O-ringFKM
10FlangeNickel-plated surface (stainless steel variant)
11CoilEpoxy

Dimensions

Threaded variant

INFO

Dimensions in mm. Variants according to industry standard form B.

BURKERT 389794 Dimensions threaded variant

Port connectionA [mm]B [mm]C [mm]D [mm]
Thread CF A - M552010-

Performance Specifications

Power consumption for standard variant, coil size 24.5 mm:

Inrush ACHold ACDC ColdDC WarmOpening TimeClosing Time
14 VA8 VA / 6 W--8...15 ms10...17 ms

Ordering Information

Standard variant according to industry standard form B, coil size 24.5 mm.

WARNING

All valves are delivered without a cable plug.

Circuit functionPort connectionOrifice [mm]Kv value water [m³/h]Voltage/Frequency/PowerPressure range [bar]Body materialArticle no.
CF AM52.00.110230/50/60...22Stainless steel389794