Burkert 323684 Type 6213 servo-assisted 2/2-way solenoid valve. Features a brass body, G1 internal thread, NBR seal, and 24V operation for neutral media up to 10 bar.

Burkert 323684 Type 6213 is a servo-assisted 2/2-way diaphragm valve designed for controlling, shutting off, and dosing neutral media with a viscosity of up to 21 mm²/s. The spring coupling of the diaphragm supports the opening process in the valve. In its standard variant, the valve requires a minimum differential pressure for full opening. The 323684 model features a brass body, NBR seal, G1 internal thread, and operates on 24V. To reduce electrical power consumption during operation, coils with integrated Kick-and-Drop (KD) electronics featuring double coil technology are available.
| Property | Specification |
|---|---|
| Seal Material | NBR, FKM, EPDM |
| Body Material | Brass acc. to DIN EN 50930-6, Stainless steel 1.4408 |
| Coil Material | Polyamide, epoxy (insulation class H) |
| Orifice | Standard: DN 10...DN 40 |
| Duty Cycle | 100% continuous operation; KD coil max. 6 switching cycles/minute |
| Voltage Tolerance | ±10% |
| Degree of Protection | IP65 with cable plug Type 2518 |
Circuit function A (CF A): 2/2-way solenoid valve, servo-controlled, normally closed.

| No. | Element | Material |
|---|---|---|
| 1 | Nut | Steel (thick-film passivated), Stainless steel 1.4305, PTFE-coated |
| 2 | Coil | Polyamide or epoxy |
| 3 | Stopper | Stainless steel 1.4113 |
| 4 | Shading ring | Copper (Cu) with brass body; Silver (Ag) with stainless steel body |
| 5 | Magnetic core | Stainless steel 1.4113 |
| 6 | O-ring | FKM |
| 7 | Plunger seal | NBR, FKM, EPDM |
| 8 | Bonnet | PA6 |
| 9 | Cover | DN 10...DN 25: stainless steel 1.4301; DN 40: brass, stainless steel 1.4408 |
| 10 | Spring | Stainless steel 1.4310 |
| 11 | Diaphragm | NBR, FKM, EPDM |
| 12 | Diaphragm support | PPSGF40 in combination with brass or stainless steel parts |
| 13 | Valve body | Brass, stainless steel 1.4408 |

| DN | A | B | C | D | E | G | L | SW | Coil size |
|---|---|---|---|---|---|---|---|---|---|
| 10 | 71.1 | 82.1 | 36 | 46 | 22 | G 1/4, G 3/8 | 50 | 22 | 5 and 6 |
| 13 | 82.6 | 95.9 | 44.5 | 56.7 | 27.25 | G 1/2 | 58 | 27 | 5 and 6 |
| 20 | 99.6 | 120.1 | 65 | 76.6 | 37.5 | G 1 | 80 | 41 | 5 and 6 |
| 25 | 143.4 | 163.4 | 77 | 88 | 46 | G 1 | 95 | 41 | K and L |
| 40 | 165.4 | 200.4 | 104.5 | 117 | 64 | G 2 | 132 | 70 | K and L |

| Coil size | H | J | K | O | M |
|---|---|---|---|---|---|
| 5 | 32 | 20.5 | 45 | 41 | 3.4 |
| 6 | 40 | 23.5 | 51 | 41 | 3.4 |
| K | 42 | 27 | 55.5 | 64 | 7 |
| L | 65 | 37.5 | 72 | 64 | 7 |
Risk of injury from high pressure
Before loosening lines or valves, switch off the pressure and vent the lines.
Risk of injury from electric shock
Before reaching into the device or the system, switch off the power supply and secure it against reactivation. Observe the applicable accident prevention and safety regulations for electrical devices.
Installation Position
The installation position is optional, but preferably with the actuator upright.
Risk of injury due to improper maintenance
Maintenance may be carried out by authorised technicians only and with the appropriate tools. Secure the system against unintentional activation.
Solenoid Installation:
Troubleshooting: