Burkert 311810 (Type 2871) is a direct-acting 2-way proportional valve featuring a 0.6 mm orifice, stainless steel body, FKM seal, and G 1/8 thread for demanding control tasks.

Burkert 311810 (Type 2871) is a direct-acting solenoid control valve used as the regulating unit in process control loops. Due to an elastomeric seat seal, the valve closes tight (integrated shut-off function) up to the DN specific nominal pressure. The plunger of the valve is assembled frictionless, which leads to an extraordinary adjustment characteristic. This valve is particularly suitable for demanding control tasks involving high control ranges and dry gases.
| Product Properties | Value |
|---|---|
| Seal Material | FKM, EPDM |
| Body Material | Brass, stainless steel |
| Hysteresis | < 5 % |
| Repeat Accuracy | < 0.25 % FS |
| Response Sensitivity | < 0.25 % FS (< 0.1% FS with DN < 0.8 mm) |
| Setting Range | 1:200 (DN 0.8...2), 1:500 (DN 0.05...0.6) |
| Actuating Time (10...90%) | < 15 ms |
| Pressure Range | 0...12 bar (also applicable for technical vacuum) |
| Duty Cycle | 100 % continuous operation |
| Operating Voltage | 24 V DC (12 V on request) |
| Power Consumption | Max. 5 W |
| PWM Frequency | 1500 Hz |
| Degree of Protection | IP65 |
Circuit function A (CF A): 2/2-way solenoid proportional control valve, direct-acting, normally closed.

Threaded Variant

| Port connection | A | B |
|---|---|---|
| G 1/8 | 8 mm | - |
| NPT 1/8 | 7 mm | - |
Exemplary Characteristic Curve

Sizing Recommendation
The dimensioning of the nominal diameter is very important for proportional valves to function properly within the application. The nominal diameter must be selected so that the desired flow range is achieved and, when the valve is fully open, a sufficient portion of the total pressure drop occurs across the valve. Reference value: Δp_valve > 25% of the total pressure drop. If the differential pressure exceeds half the value of the nominal pressure, discontinuities may occur.
Valve control takes place through a PWM signal (pulse-width modulation). The duty cycle of the PWM signal determines the coil current and hence the position of the plunger. The Bürkert control electronics Type 8605 converts an analogue signal to a reference value corresponding to the valve type PWM signal and provides additional functions such as temperature compensation (coil heating), ramp function, and the adjustment of minimum and maximum duty cycle/coil current for the control range.
WARNING
Risk of injury due to high pressure and escaping medium. Switch off the pressure before working on the device or system. Vent or drain the pipes.