Skip to content
DN 250-10 barEPDM High-Temp316L Cast BodyAutoclavable

BURKERT 20133890 (Type 2973) 2/2-Way Manual Diaphragm Valve

BURKERT 20133890 (Type 2973) 2/2-way manual diaphragm valve. Features DN 25 welded connection, EPDM high-temperature diaphragm, 316L investment cast body, and handles 0-10 bar pressure.

BURKERT 20133890 (Type 2973) 2/2-Way Manual Diaphragm Valve

BURKERT 20133890 (Type 2973) is a 2/2-way diaphragm valve with a manually operated actuator (FullFunction). The manual actuator with a plastic handwheel ensures use in hygienic or aggressive ambient conditions. The flow-optimized valve body with minimum dead space enables high flow values of up to 14.6 m³/h. The actuator has a compact, autoclavable design and possesses a visual position indicator with a reproducible stroke scale. It also features an adjustable minimum and maximum stroke limitation and locking mechanism.

BURKERT 20133890 Type 2973 manual diaphragm valve overview

Material Specifications ​

The 20133890 model features an investment cast 316L/1.4435 stainless steel body and an EPDM high-temperature diaphragm, suitable for medium temperatures from -10 °C to +143 °C.

BURKERT 20133890 material specifications diagram

No.ElementMaterial
1Lock pinStainless steel 1.4305
2ScrewStainless steel A2
3Handwheel coverPolyamide (PA)
4HandwheelPolyphenylene sulphide (PPS)
5Visual position indicatorPolyamide (PA)
6Valve spindleStainless steel 1.4305
7Diaphragm socketStainless steel 1.4308
8DiaphragmEPDM high-temperature
9Valve bodyInvestment cast material 316L/1.4435

Dimensions ​

Manual Actuator ​

BURKERT 20133890 manual actuator open position dimensions

Diaphragm sizeH1H2H3H4∅ B
2514314913313945

INFO

Dimensions in mm, unless otherwise stated.

Cast Valve Body (VG) with Welded Connection ​

BURKERT 20133890 cast valve body with welded connection dimensions

Diaphragm sizePort connection∅D1sLhH
251" (ASME BPE)25.41.6511420.039.0

Performance Specifications ​

Flow Characteristics ​

Diaphragm sizePort connectionKv value water [m³/h]
251"14.6

Medium Pressure ​

Diaphragm sizeMaximum static operating pressure [bar]Tightening torque (EPDM) [Nm]
25101.2

WARNING

The tightening torques refer to the static media pressures specified above. Excessive torque can shorten the service life of the diaphragm. A tolerance of +10% applies to the tightening torques specified.

Installation Notes ​

It is the responsibility of the installer and the operator to ensure self-draining. The marking on the port connection of the valve body serves as an orientation aid and must point upwards. The actual self-draining angle must be set with a suitable measuring tool.