Skip to content
Direct-actingMedia-separatedPivoted armatureIP65

BURKERT 20128245 Type 0331 3/2-Way Direct-Acting Solenoid Valve

BURKERT 20128245 Type 0331 direct-acting 3/2-way pivoted armature solenoid valve. Features PVDF body, FKM seal, flange connection, 24V DC, and 0-4 bar pressure range.

BURKERT 20128245 Type 0331 3/2-Way Direct-Acting Solenoid Valve

BURKERT Type 0331 (Article 20128245) is a direct-acting, media-separated pivoted armature solenoid valve. It is configured as a 3/2-way valve with circuit function T, allowing for universal use depending on the application. The solenoid coils are moulded with a chemically resistant epoxy. Since the coil system is separated from the medium by a diaphragm, the valve is especially suitable for critical media such as aggressive acids and lyes.

BURKERT 20128245 Type 0331 direct-acting pivoted armature solenoid valve

This specific model features a PVDF (Polyvinylidene fluoride) body and FKM (Fluor rubber) seals, ensuring high chemical resistance. It operates on 24V DC, handles a pressure range of 0 to 4 bar, and utilizes a Bürkert flange 32 x 46 version A2 connection. The valve is equipped with a manual override for service-friendly start-up and testing.

General Technical Data ​

PropertySpecification
Orifice3.00 mm (DN 3)
Body MaterialPVDF (Polyvinylidene fluoride)
Seal MaterialFKM (Fluor rubber)
Voltage24 V DC
Pressure Range0 - 4 bar
Medium Temperature0 °C to +80 °C
Ambient TemperatureMax. +55 °C
ViscosityMax. 37 mm²/s
Degree of ProtectionIP65 with correctly connected cable plug
Installation PositionAs required, preferably with actuator upright

Duty Cycle

For PP and PVDF bodies, the duty cycle is 40% (60% intermittent operation) in 30 min for the 8 W variant, or 100% continuous operation for the 5 W variant.

Circuit Function ​

The 20128245 model operates with Circuit Function T (CF T).

BURKERT 20128245 Type 0331 circuit function T diagram

Circuit function T (CF T): 3/2-way solenoid valve, direct-acting, flow direction optional, normally closed.

Dimensions ​

The following dimensions apply to the plastic body variant (PVDF).

BURKERT 20128245 Type 0331 plastic body dimensions

(Note: Dimensions in mm. The dimensions of the cable plug Type 2518 or 2509 can be found in their respective data sheets.)

Installation and Safety ​

DANGER!

Risk of injury from high pressure in the system/device ▶ Before working on equipment or device, switch off the pressure and deaerate/drain lines.

Risk of injury from electric shock ▶ Before working on the system or device, switch off the power supply and secure against reactivation. ▶ Observe the applicable accident prevention and safety regulations for electrical devices.

Before Installation ​

  • The installation position is flexible, but preferably with the actuator at the top.
  • Check pipelines for soiling and clean if required.
  • For safe operation of the solenoid valve, a dirt trap (≤ 500 µm) must be installed before the valve inlet.

Electrical Connection ​

  • Connect L1/+ and N/– to terminals 1 and 2 independently of the polarity.
  • Connect the protective conductor.
  • Attach valve seat and check that it fits properly.
  • Screw the cable plug in place, observing the maximum torque of 1 Nm.
  • Check electrical continuity between coil and body (protective conductor function).