Burkert Type 8652 AirLINE valve island (SKU 20120520) optimized for process automation. Features LC display diagnostics, PROFINET/EtherNet/IP support, and ATEX Zone 2 approval.

Burkert Type 8652 AirLINE valve island (SKU 20120520) is developed for process automation requirements. Diagnostic functions can be visualised on the LC display in clear text and symbols, simplifying the assignment of messages and saving time during start-up and maintenance. Diagnostic messages are also available at the controller for a fast overview of the plant status. The hardware is optimised for installation at the bottom of the control cabinet, with standard rail installation also possible. Key pneumatic functions, such as check valves in the exhaust air ducts, prevent unplanned actuation due to pressure peaks.
| Product properties | Specification |
|---|---|
| Material | |
| Body | PA (polyamide) |
| Seal | NBR and PUR |
| Width per station | 11 mm |
| Manual override | Latching, spring return (optional: lockable) |
| Number of valve slots | Max. 24 |
| Maximum number of valve functions | Max. 48 |
| Pneumatic intermediate supply | Optional for the variants with 16, 20 and 24 valve slots |
| Performance data | |
| Pressure data | Overpressure to atmospheric pressure |
| Pressure range | Vacuum to 10 bar |
| External supply air (auxiliary pilot air) | 3 to 10 bar |
| Flow rate QNn value air | 310 l/min (measured at +20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure) |
| Flow rate QNn value air with Hot Swap | Flow reduced by approx. 3 % |
| Nominal operating mode | Continuous operation (100 % duty cycle) |
| Electrical data | |
| Operating voltage | 24 V DC (Voltage tolerance ±10 %) |
| Nominal power of each valve | 0.7 W (0.175 W after power reduction) |
| Nominal current of each valve | 29 mA (10 mA after power reduction) |
| Digital input | Max. 48 |
| Protection class | III according to DIN EN 61140, VDE 0140 |
| Medium data | |
| Operating medium | Oil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended) |
| Compressed air quality | ISO 8573-1: 2010, Class 7.4.4 |
| Environment and installation | |
| Ambient temperature | -10 °C to +55 °C |
| Storage temperature | -20 °C to +60 °C |
| Degree of protection | IP20, IP65 in closed control cabinets |
AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve terminal is adapted directly to the control cabinet floor or control cabinet wall.

| Product properties | Specification |
|---|---|
| Material | |
| AirLINE Quick Adapter Plate | Stainless steel 1.4301, Anodised aluminium |
| Pneumatic connection | Stainless steel 1.4401, Nickel-plated brass |
| Valve functions per station | 8, 16, 24, 32, 40 and 48 |
| Product connections | |
| Pneumatic Supply / Exhaust | Push-in D 10 mm, 3/8" |
| Pneumatic working ports | Push-in D 6 mm, 1/4" |
| Circuit function | Description |
|---|---|
| C (CF C) | 3/2-way solenoid valve. Servo-controlled, with manual override. Normally closed. |
| C (CF C) | 2 × 3/2-way solenoid valve. Servo-controlled, with manual override. Normally closed. |
| D (CF D) | 2 × 3/2-way solenoid valve. Servo-controlled, with manual override. Normally open. |
| H (CF H) | 5/2-way solenoid valve. Servo-controlled, with manual override. Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. |
| L (CF L) | 5/3-way solenoid valve. With manual override. In middle position all ports locked. |
| M (CF M) | 5/3-way solenoid valve. Servo-controlled, with manual override. In middle position ports 2 and 4 ventilated. |
| N (CF N) | 5/3-way solenoid valve. With manual override. In middle position ports 2 and 4 exhausted. |
| Z (CF Z) | 5/2-way solenoid valve. Impulse variant with 2 coils and manual override. Pressure applied via port (1), therefore one of the two ports (2) or (4) is under pressure. |

| Variant | A | B | C | D | m | m' | n |
|---|---|---|---|---|---|---|---|
| 16-fold with intermediate supply | 112 | 224 | 10 x M5 | 114.3 | 7 | 7 | 4 |
| 20-fold with intermediate supply | 134 | 268 | 10 x M5 | 158.3 | 11 | 7 | 5 |
| 24-fold with intermediate supply | 156 | 312 | 10 x M5 | 158.3 | 11 | 11 | 6 |
| 16-fold without intermediate supply | 99 | 198 | 10 x M5 | - | 15 | - | 4 |
| 20-fold without intermediate supply | 121 | 242 | 10 x M5 | - | 19 | - | 5 |
| 24-fold without intermediate supply | 143 | 286 | 10 x M5 | - | 23 | - | 6 |
(Dimensions in mm, unless otherwise stated)
| Spring-loaded terminal 5-pin | Colour | Assignment |
|---|---|---|
| Pin 1 | Red | 24 V DC |
| Pin 2 | White | CAN_H (büS connection) |
| Pin 3 | Green | SHIELDING |
| Pin 4 | Blue | CAN_L (büS connection) |
| Pin 5 | Black | GND |
| Spring-loaded terminal 2-pin | Clip | Colour | Assignment |
|---|---|---|---|
| Pin 1 | 1 | Red | AUX 24 V |
| Pin 2 | 2 | Black | GND |
INFO
The interface plate has a 2-pin spring-loaded terminal to which the pneumatic valves’ power supply is connected.
To use the Hot Swap function, always observe a minimum distance to the front edge of the control cabinet when installing the valve island inside the control cabinet.

The digital inputs are supplied (24 V) by the electronic module. Current is limited to maximum 30 mA per digital input. Standard 3-wire sensors and 2-wire sensors with voltages between 10…30 V as well as mechanical limit switches can be used.
Type 6534 valves are equipped with additional connection terminals. A valve circuit can therefore be interrupted by an external switch. Manual override is not required for these valve variants. To use the shut-off function, connect the terminal to a potential-free contact (mechanical switch or relay).
The following illustration shows a network with the example of AirLINE Type 8652 with Industrial Ethernet variant as master valve terminal and various AirLINE Type 8652 with büS variant as slave valve terminals.

DANGER
Danger from electrical voltage
WARNING
Danger of explosion due to electrostatic charge
INFO
Special conditions for safe use