Skip to content
Media SeparationFast Switching< 45 dB(A)IP30

BURKERT 20100157 Type 6757 WhisperFlipper Valve with Media Separation

Burkert 20100157 Type 6757 WhisperFlipper 2/2-way normally closed solenoid valve. Features 3.0mm orifice, PEEK body, FKM seal, and 24V DC operation for medical and analytical applications.

BURKERT 20100157 Type 6757 WhisperFlipper Valve with Media Separation

Burkert 20100157 Type 6757 WhisperFlipper is a 2/2-way normally closed solenoid valve with media separation. Designed for medical technology, in-vitro diagnostics (IVD), and environmental analysis, the valve handles flushing, cleaning, and disinfection cycles involving high temperatures or pressures. The 20100157 configuration features a 3.00 mm orifice, PEEK body, FKM seals, and G 1/4 threaded connections, operating on 24 V DC.

The Type 6757 family provides fast switching times of approximately 7 ms, ensuring high process safety and accurate dosing. The compact 18 mm installation width and low switching noise (< 45 dB(A)) make it suitable for integration into compact analytical devices and clinical equipment.

Burkert 20100157 Type 6757 threaded variant G 1/4 PEEK with rectangular plug

General Technical Data ​

PropertyValue
OrificeDN 1.4 to DN 4.0 (SKU 20100157: 3.0 mm)
Circuit functionA, B, and T
Typical service life10 million switching cycles (laboratory endurance test)
Duty cycle (Single)100% continuous operation
Duty cycle (Block)70% continuous operation (max. 10 min. duty cycle)
Switching noise45 dB(A)
Switching timeOpening: approx. 7 ms; Closing: approx. 7 ms
Operating voltage12 V DC, 24 V DC (SKU 20100157: 24 V DC)
Nominal power12 V: 5.0 W; 24 V: 4.5 W
Voltage tolerance± 5% (including residual ripple)
Medium temperatureFKM: 0 °C to +50 °C (+90 °C permissible for max 30 min cleaning)
ViscosityMax. 21 mm²/s
Degree of protectionIP30 according to EN 60529

Temperature Limit

The maximum body temperature must not exceed +110 °C. In continuous operation, ensure sufficient heat dissipation (convection) on the metal surface of the valve. The valve must not be cycled during flushing cycles.

Circuit Functions ​

SymbolDescription
Burkert 20100157 Type 6757 circuit function A normally closedCircuit function A (CF A)
2/2-way solenoid valve
Direct-acting
Normally closed

Materials ​

Burkert 20100157 Type 6757 material specifications and components

No.ElementMaterial
1CoverPA
2Coil housingNickel-plated
3Valve housingPPS
4Diaphragm (Wetted)FFKM, EPDM, FKM (SKU 20100157: FKM)
5Valve body (Wetted)PEEK, PPS (SKU 20100157: PEEK)
6Sub-base seal (Wetted)FFKM, EPDM, FKM
7Oval head screwStainless steel

Installation and Operating Conditions ​

Fluidic Installation ​

Install a dirt trap in the direction of the current before the valve (recommended mesh width 5 μm). For nominal diameter 3 or 4 with G 1/8 threaded connection, ensure that the screw connections have a sufficiently large cross-section.

Block Structure Limits

For circuit functions T and B, specific pressure range restrictions apply in block structures depending on the width per station and duty cycle. Minimum permitted width per station is 18.5 mm.

Electrical Installation ​

The correct polarity is a prerequisite for the function of the valve. The connection between the stranded housing and the square connector is designed as a non-detachable connection. Ensure that the stranded housing is firmly locked into the square connector during installation.

Dimensions ​

Threaded Variant (G 1/8 and G 1/4)

Burkert 20100157 Type 6757 dimensions for threaded variant

Port connectionAB
G 1/49 mm9 mm
G 1/87 mm7 mm