Skip to content
ATEX/IECEx Zone 2PROFINET S2Hot Swap

BURKERT 20100150 8652 AirLINE Valve Island

Burkert Type 8652 AirLINE valve island for process automation. Features up to 24 valve slots, LC display diagnostics, PROFINET S2 redundancy, and ATEX/IECEx Zone 2 explosion protection.

BURKERT 20100150 8652 AirLINE Valve Island

Burkert Type 8652 AirLINE valve island has been especially developed for process automation requirements. New diagnostic functions can be visualised on the LC display, both in clear text as well as symbols. This makes it easy to relate to the shown messages and helps to save time during start-up and maintenance. Furthermore, the diagnostic message is also available at the controller, enabling a fast overview of the plant status. The hardware is optimised for installation at the bottom of the control cabinet, while installation on a standard rail is also possible. Key pneumatic functions ensure increased process reliability, such as check valves in the exhaust air ducts that prevent unplanned actuation due to pressure peaks.

BURKERT 20100150 Burkert 8652 AirLINE valve island overview

  • Safety-related shut-off of valves possible
  • Higher plant availability with PROFINET S2 (system redundancy)
  • Process reliability through pneumatic functions
  • Optimised for installation at the bottom of the control cabinet
  • EX-variants: ATEX / IECEx Zone 2, CCC, cURus HazLoc CL I, II, III Div 2

General Technical Data ​

Product propertiesDescription
Body MaterialPA (polyamide)
Seal MaterialNBR and PUR
Width per station11 mm
Manual overrideLatching, spring return (optional: lockable)
Number of valve slotsMax. 24
Maximum valve functionsMax. 48
Pressure rangeVacuum to 10 bar
External supply air3 to 10 bar
Flow rate QNn value air310 l/min (measured at +20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure)
Operating voltage24 V DC (±10%)
Nominal power per valve0.7 W (0.175 W after power reduction)
Nominal current per valve29 mA (10 mA after power reduction)
Operating mediumOil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended)
Ambient temperature-10 °C to +55 °C
Degree of protectionIP20, IP65 in closed control cabinets

AirLINE Quick ​

AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve terminal is adapted directly to the control cabinet floor or control cabinet wall.

Advantages:

  • Reduced space requirement in the control cabinet
  • Makes it possible to use more compact control cabinets
  • Reduced installation effort due to hose connections directly at the bottom of the control cabinet
Product propertiesDescription
AirLINE Quick Adapter PlateStainless steel 1.4301, Anodised aluminium
Pneumatic connectionStainless steel 1.4401, Nickel-plated brass
Valve functions per station8, 16, 24, 32, 40 and 48
Pneumatic Supply / ExhaustPush-in D 10 mm, 3/8"
Pneumatic working portsPush-in D 6 mm, 1/4"

BURKERT 20100150 Burkert 8652 AirLINE Quick Adapter in stainless steel or anodised aluminium

Approvals and Conformities ​

  • Explosion protection: Optional ATEX/IECEx (II 3G Ex ec IIC Gc / II 3D Ex tc IIIC Dc). As a category 3 device suitable for zone 2/22.
  • North America (USA/Canada): Optional UL Listed (UL 61010-1) and UL Recognized for Hazardous Locations (Class I, Zone 2; Class II, Zone 22; Class I, Division 2).
  • China Compulsory Certification (CCC): Optional for hazardous applications in China.

Explosion Protection Safety Notes

When using the device in potentially explosive atmospheres (ATEX Zone 2/22):

  • Voltage Hazards: Connect or disconnect terminals (24 V supply, SIA, EVS, digital inputs) only in a de-energized state.
  • Hot Swap: The use of the Hot Swap function is prohibited in an existing explosive atmosphere. It is only permitted if the absence of an explosive atmosphere is ensured and verified by suitable testing equipment.
  • Electrostatic Charge: Clean the device surface only by wiping gently with a damp or antistatic cloth to prevent explosion risks from electrostatic discharge.

Dimensions ​

Variant 4-, 8- and 12-fold ​

BURKERT 20100150 Burkert 8652 dimensions for 4-, 8- and 12-fold variants

Variant 16-, 20- and 24-fold ​

BURKERT 20100150 Burkert 8652 dimensions for 16-, 20- and 24-fold variants

Product Installation ​

To use the Hot Swap function, always observe a minimum distance to the front edge of the control cabinet when installing the valve island inside the control cabinet.

BURKERT 20100150 Burkert 8652 installation situation inside the control cabinet

Product Design and Assembly ​

BURKERT 20100150 Burkert 8652 interface plate 24V without modular shut-off

Electronic Module with Digital Inputs (Optional) ​

The digital inputs are supplied (24 V) by the electronic module. Current is limited to maximum 30 mA per digital input. Standard 3-wire sensors and 2-wire sensors with voltages between 10…30 V as well as mechanical limit switches can be used.

Type 6534 valves are equipped with additional connection terminals. A valve circuit can therefore be interrupted by an external switch. Manual override is not required for these valve variants. To use the shut-off function, connect the terminal to a potential-free contact (mechanical switch or relay).

Example Configuration ​

The following illustration shows a network with the example of AirLINE Type 8652 with Industrial Ethernet variant (PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, CC-Link IE Field Basic) as master valve terminal and various AirLINE Type 8652 with büS variant as slave valve terminals.

BURKERT 20100150 Burkert 8652 example network configuration with Industrial Ethernet