Armstrong TV-2 balanced pressure thermostatic air vent for positive venting of air from chamber type heat transfer equipment. Features cast bronze body and stainless steel valve.

Armstrong TV-2 Balanced Pressure Thermostatic Air Vent provides positive venting of air from chamber type heat transfer equipment with no loss of steam. Typical applications include jacketed kettles, retorts, vulcanizers, jacketed sterilizers, or other contained equipment where air could accumulate at the top of the steam chamber and reduce heat transfer capacity.
The Model TV-2 responds to the pressure-temperature curve of steam at any pressure from light vacuum to maximum operating pressure. Air is automatically vented at slightly below steam temperature throughout the entire operating pressure range. The thermostatic element is a charged multi-convolution phosphor bronze bellows caged in stainless steel. The valve and seat are also stainless steel, designed to meet the most rigid cycling specifications known for this type of service.

| Name of Part | Material |
|---|---|
| Body & Cap | Cast bronze ASTM B62 |
| Gasket | Compressed non-asbestos |
| Thermostatic Unit Bellows Cage and Cover | Phosphor bronze, Stainless steel |
| Thermostatic Unit Gasket | Copper clad |
| Specification | Value |
|---|---|
| Pipe Connections | 3/8", 1/2" (10 mm, 15 mm) |
| "A" (Diameter) | 2-3/16" (56 mm) |
| "B" (Height) | 3-1/2" (89 mm) |
| Weight | 1 lb. 9 oz. (0.8 kg) |
| Maximum Operating Pressure | 125 psig (9 bar) |
| Maximum Temperature | 350°F (177°C) |

Armstrong Model TV-2 Thermostatic Air Vents should be installed at the highest points of steam chambers with inlet connections to the vents higher than the highest points of the chambers. Thus installed, there is a minimum hazard of any liquid carryover and air can be vented to atmosphere with no drain line necessary.
Fig. 2-1. Installation on a retort.
Fig. 2-2. Installation on a sterilizer.
Fig. 2-3. Installation on a vulcanizer.
Fig. 2-4. Installation on jacketed kettles.
Equipment under pressure
Operating temperature > 100°C (212°F). Make sure the vent is cold and depressurized before handling!
Explore similar products in our catalog