Armstrong SH-1700 Bimetallic Steam Trap for Superheat Applications

Armstrong SH-1700 series bimetallic steam trap for superheat applications. Features titanium valve and seat, forged chrome-moly steel body, max pressure 1990 psig at 1004°F.

Armstrong SH-1700 Bimetallic Steam Trap for Superheat Applications

Armstrong SH-1700 Series superheat steam traps operate by the effect that rising temperature has on the bimetallic elements. At start-up the valve is wide open, which allows a large volume of non-condensables and cold condensate to be removed from the system. When the trap reaches steam temperature, the bimetallic elements pull the valve into the seat closing the trap. The valve remains closed until the bimetallic elements cool, thus allowing the valve to crack open, vent the condensate and non-condensables, and then close again when steam temperature is reached.

The SH Series superheat steam traps adjust automatically to changing conditions. The SH-1700 series utilizes titanium valves and seats to ensure extremely long service life in the harsh environment of superheated steam systems.

Armstrong SH-1700 bimetallic steam trap

Features and Benefits

  • Adjusts automatically to changing conditions
  • Equipped with titanium valve and seat for extremely long service life in harsh environments
  • Forged chrome-moly steel construction with integral stainless steel strainer
  • In-line repairable
  • Stacked nickel-chrome bimetal operator with titanium valve and seat
  • Capable of operation on low load and superheat applications throughout its pressure/temperature range

Specifications

Steam trap shall be a bimetallic style. The trap shall be forged chrome-moly steel with integral stainless steel strainer, in-line repairable. The mechanism shall consist of a stacked nickel-chrome bimetal operator, with titanium valve and seat. The steam trap shall be capable of operation on low load and superheat applications throughout its pressure/temperature range.

Maximum Operating Conditions

  • Maximum allowable pressure (vessel design): 1,990 psig @ 1,004°F (137.2 barg @ 540°C)
  • Maximum operating pressure: 1,800 psig (124.1 barg)
  • Suggested minimum operating pressure: 600 psig (41.3 barg)

Materials

ComponentMaterial
Body and CapASTM A-182 F91
ValveTitanium
SeatTitanium
Bimetallic ElementsNickel-chrome and stainless steel
ScreenStainless Steel
BoltsASTM A193 Gr. B8C
NutsASTM A194 Gr. 8C

Dimensions and Weights

ModelSH-1700 (in)SH-1700 (mm)
Pipe Connections1/2, 3/4, 115, 20, 25
“B” (Height)5-3/16148
“C” (End-to-End) - Socket Weld12-3/8315
“C” (End-to-End) - Butt Weld12-3/8315
“D” (Centerline to Top)4-13/16123
“E” (Width)5127
Weight - SW/BW33 lb15.0 kg

INFO

Consult factory for weight and dimensions of flanged connections.

Armstrong SH-1700 dimensional drawing

Performance Charts

Model SH-1700 Cold Water CapacityArmstrong SH-1700 cold water capacity chart

Model SH-1700 Pressure/Temperature RatingArmstrong SH-1700 pressure and temperature rating chart

How to Order

  • Specify model number
  • Specify maximum operating pressure
  • Specify size and type of pipe connections
  • When flanges are required specify type of flange